Use this URL to cite this publication: https://hdl.handle.net/20.500.14911/210690
Influence of atmospheric effects on the performance of stell structures protected by fire protection coatings
Publication Type (CRIS)
Straipsnis recenzuojamoje užsienio konferencijos medžiagoje / Article in peer-reviewed foreign conference proceedings (P1g)
Publication Type (eLABa)
Straipsnis recenzuotame konferencijos darbų leidinyje / Article published in peer-reviewed conference proceedings (P1d)
VILNIUS TECH Research Priorities and Topics
Aplinką tausojančios statybinės medžiagos ir technologijos / Low emissions building materials and technologies (SD0202)
Lithuanian Intelligent Specialization
Nauji gamybos procesai, medžiagos ir technologijos / New production processes, materials and technologies (L104)
Title [en]
Influence of atmospheric effects on the performance of stell structures protected by fire protection coatings
Džigita Nagrockienė, Mindaugas Grigonis
Is part of
Problems of Emergency Situations = Проблеми надзвичайних ситуацій: Матеріали Міжнародної науково-практичної конференції, Черкаси, 14 травня 2025 року
Published In
| Year | Start Page | End Page |
|---|---|---|
2025 | 185 | 186 |
Publisher
Черкаси : Національний університет цивільного захисту України
Extent
p. 185-186
URI
| URI | Access Rights |
|---|---|
| https://hdl.handle.net/20.500.14911/210690 | |
| leidinys internete | Viso teksto dokumentas (atviroji prieiga) / Full Text Document (Open Access) |
| https://talpykla.elaba.lt/elaba-fedora/objects/elaba:236823661/datastreams/MAIN/content | |
| https://talpykla.elaba.lt/elaba-fedora/objects/elaba:236823661/datastreams/ATTACHMENT_264377008/content |
Cited references
4
Science / Art Area
Technologijos mokslai / Technological sciences (T)
Field of Science / Art
Statybos inžinerija / Civil engineering (T002)
Abstract (en)
The effectiveness and durability of the painted fire protection coatings are not in doubt, they are certified and comply with all fire protection requirements, but it has not been established how they will survive when they are used in the areas of the coastal region where they may be exposed to aggressive environments that may arise from the production, handling and storage of various chemical substances. Under certain conditions and after six months, they may become thermally conductive and lose their mechanical resistance, which in the event of a fire could have a decisive impact on the safety of the buildings and the occupants of the buildings.
Resource Type (COAR)
TextConference outputConference proceedingsConference paper
Language
Anglų / English (en)
Country
Ukraina / Ukraine (UA)
Owning collection
eLABa ID
236823661
Access Rights