Use this URL to cite this publication: https://hdl.handle.net/20.500.14911/127775
Vilniaus TE-2 mechaninio cecho apšiltinimas ir šilumos sąnaudų jame mažinimo galimybės
Publication Type (CRIS)
Straipsnis kitame recenzuojamame leidinyje / Article in other peer-reviewed edition (S5)
Publication Type (eLABa)
Straipsnis kitame recenzuotame leidinyje / Article in other peer-reviewed publication (S4)
Author(s)
| Author | Affiliation |
|---|---|
Gluosnis, Aleksandras Eduardas | Kauno technologijos universitetas |
Valentukevičius, Gintaras |
Title [lt]
Vilniaus TE-2 mechaninio cecho apšiltinimas ir šilumos sąnaudų jame mažinimo galimybės
A. Gluosnis, G. Valentukevičius
Title in other language [en]
Renovation of mechanical shop of Vilnius thermal power station-2 and possibilities of decreasing heat losses in it
Is part of
Aplinkos inžinerija = Environmental engineering
Published In
| Year | Issue | Start Page | End Page |
|---|---|---|---|
1995 | 2(4) | 42 | 48 |
Publisher
Vilnius : Technika
Extent
p. 42-48
Science / Art Area
Technologijos mokslai / Technological sciences (T)
Field of Science / Art
Aplinkos inžinerija / Environmental engineering (T004)
Abstract (en)
Mechanical shop of Vilnius TE-2 is one-floor building, height 7.3 m, without ceiling. A lot of heat is being lost through the roof and big windows. In order to save heat and decrease these losses we suggest to install intermediate ceiling using PV-AIM rockwool mats covered with glass fibres or to implement polietilentereftelat pellicle into windows. It was created a room heat balance for building and its renovation. It was calculated that needed heat energy after ceiling installation would decrease from 11.724 to 4640 W. After installation of recirculating air heating and ventilation systems 1051 GJ or 23.877 Lt would be saved per heating season.
Resource Type (COAR)
TextJournalJournal articleResearch article
Language
Lietuvių / Lithuanian (lt)
Country
Lietuva / Lithuania (LT)
Owning collection
ISSN (of the container)
1392-1622
eLABa ID
3558304