Mathematical modelling of biofilter effectiveness in pH regimes
| Year | Start Page | End Page |
|---|---|---|
2011 | 408 | 414 |
| URI | Access Rights |
|---|---|
| https://hdl.handle.net/20.500.14911/135601 | |
| Straipsnis | Viso teksto dokumentas (atviroji prieiga) / Full Text Document (Open Access) |
Moreover, the dependence of the filter efficiency on its charge height (0.15–0.75 m) with different initial pollutants (xylene, butanol and buyl acetate) concentrations and at different velocity of passing air (0.02–0.1 m/s) were modelled. Similar to experimental tests, the increase in the charge height from 0.15 to 0.75 m results in the increase in cleaning efficiency. For example, when the pH of 7 is maintained in the biocharge and the air is being cleaned of butyal acetate (with its initial concentration of 74 mg/m³) the efficiency of removal of butyl acetate starting with the height of the charge equal to 30 m is 70.1 %, starting with the height of 60 m is 77.6 %. Furthermore, modelled expression were similar to experimental data of the air flow rate results in the decreased efficiency of the biofilter. Respectively, when the pH of 7 is maintained in the charge and the air is beeing cleaned of xylene (with its initial concentration of 63 mg/m³), with the velocity of the passing air increased from 0.04 to 0.08 m/s, air cleaning efficiency significantly reduces from 76.8 to 68.3 mg/m³. Therefore, mathematical expression of environmental processes such us biofiltration lighten theoretical calculations and seek ultimate air cleaning efficiency.