Electromagnetic disturbance-resistant controller based on the modified integral control algorithm
| Year | Issue | Start Page | End Page |
|---|---|---|---|
2025 | 1 | 16 | 20 |
| URI | Access Rights |
|---|---|
| https://hdl.handle.net/20.500.14911/210874 | |
| https://www.lik.tech/uploads/066c929e-c1b2-49e4-829b-6421c7b5f060/Zurnalas_2025_1_papildytas.pdf | Viso teksto dokumentas (atviroji prieiga) / Full Text Document (Open Access) |
| https://talpykla.elaba.lt/elaba-fedora/objects/elaba:258037393/datastreams/MAIN/content | |
| https://talpykla.elaba.lt/elaba-fedora/objects/elaba:258037393/datastreams/COVER/content |
Straipsnyje pateikiamas modifikuotu integriniu valdymo algoritmu pagrįstas grįžtamojo ryšio valdiklis, leidžiantis pasiekti didesnio valdymo sistemos atsparumo elektromagnetinių trikdžių sukeliamiems triukšmo signalams, lyginant su atvejais, kai naudojami proporcinis-integrinis-diferencinis, proporcinis-integrinis ir klasikinis integrinis valdikliai. Taip pat siūlomas valdiklis garantuoja trumpesnį valdymo sistemos atsako laiką, lyginant su klasikiniu integraliniu valdikliu. Skiriamasis siūlomo valdiklio bruožas yra tas, kad jame integrinė konstanta diskretiškai keičia savo vertę, esant tam tikrai valdymo paklaidos vertei. Valdymo sistema su pasiūlytu modifikuotu integriniu valdikliu ištirta naudojant Matlab/Simulink modeliavimo programą.
The paper presents a feedback controller based on the modified integral control algorithm, which allows achieving higher resistance to electromagnetic disturbances compared to cases when proportional-integral-derivative, proportional-integral and classical integral control algorithms are used. Also the proposed controller guaranties shorter response time of the control system as compared to the classical integral controller. Distinctive feature of the developed controller is that the integral constant changes discretely the value at a certain threshold value of the control error. The control system with the modified integral control algorithm based controller is investigated using the Matlab/Simulink simulation program.